trarzh-TWenfrdeelitfarues
Electrical Installation Controls

In accordance with the Regulation on Health and Safety Conditions in the Use of Work Equipment issued by the Ministry of Labor and Social Security, enterprises are obliged to have their existing electrical installations checked at least once a year. These checks should be done by electrical engineers, electrical technicians or high technicians. According to the aforementioned regulation principles, employees must be protected from the risk of direct or indirect contact with electricity due to all kinds of work equipment used in the enterprise. In the annexes of the Regulation (Annex 3), it is foreseen that the electrical installation, grounding installation, lightning rod installation and regular inspections of the electrical installations such as accumulators, transformers and similar electrical installations are required. can be called. When laying, rather than paying attention to the relevant parts, it is necessary to pay attention to the outer and surrounding parts.

The laying order of the installation is indicated as follows.

  • Please check the project and supply the necessary pipes, elbows, junction boxes and boxes.

  • Lay the roof pipe (according to project) before pouring the ceiling concrete of the construction.

  • To lay wall pipe, break hammer, nail and wall breaker materials and pipe, junction box and frame places in accordance with the Electrical Interior Installation Regulation.

  • Lay the wall pipes on the wall using elbows, junction boxes and boxes.

  • Fix the pipe to the wall using concrete.

With authorized organizationr Except for the above-mentioned regulation, the Grounding Regulation in Electrical Installations, Electrical Strong Current Facilities Regulation and Electrical Internal Facilities Regulation and TS EN 60079 standard must be taken into consideration in these controls performed by The controls and reports prepared in this way are in accordance with the legal regulations of occupational health and safety and are considered valid in the audits carried out by the inspectors of the Ministry of Labor and Social Security. grounding and lightning rod checks are obligatory in 1-year periods. It is necessary and obligatory to control whether the installation provides occupational health and safety. In accordance with the Occupational Health and Safety Regulation, article 353 and article 354, electrical installation control has been made obligatory and should be done by the enterprises. In addition, the Electrical Installation Control should be done not only when the facility is first installed, but also periodically as specified in the regulation.

In general, the following basic checks are required during the checks of the electrical installation: main distribution board and sub-panels, fuse boxes, machinery and teamman electric lines, sockets, generators, compressors, hydrophore pumps, lightning rods and lightning protection systems. During the controls, all fuses, switches, leakage current relays, current carrying capacities of the cables in the panels, connections of conductors in the panels, switches, fuses and leakage current in the panels. labeling of equipment such as protection devices, safety of cables in switchboards and fuse boxes against mechanical influences, continuous conduction of the earthing conductor to end-user points, safety of the panels against external mechanical effects and temperature effects and many other points are controlled, voltage drop measurements, grounding measurements , loop impedance measurements, insulation resistance measurements and other necessary measurements are carried out. Al regulations, standards and test methods published by domestic and foreign organizations.

Certification

The firm, which provides auditing, supervision and certification services to internationally recognized standards, also provides periodic inspection, testing and control services.

Contact Us

Address:

Mahmutbey Mh, Dilmenler Cd, No 2 
Bagcilar - Istanbul, TURKEY

Telephone :

+90 212 702 00 00

Whatsapp:

+90 532 281 01 42

Search